Methods of maintaining wet curtains
Water Supply Control: Water supply should ensure the cooling pads are evenly soaked. Water supply can be controlled by adjusting the water supply valve.
Uneven Wetness of the Cooling Pad Pad: Adjust the water supply valve to control the water supply, or use a higher-powered water pump or a larger-diameter water supply pipe. Regularly flush the water tank, water pump inlet, filter, and spray pipes.
Leakage Handling: Water droplets splashing off the cooling pad: Check if the water supply is too high; check for damaged cooling pads, such as tears or "flakes". Leaks at the seams: After stopping the water supply, apply silicone sealant.
Water Quality Control: Keep the water source clean, with a pH between 6 and 9. Clean the water tank and water supply system regularly. Maintain good water quality. To prevent algae or other microorganisms from growing on the cooling pad surface, add 3-5 ppm of chlorine or bromine to the water for short-term treatment. For continuous treatment, use a concentration of 1 ppm.
![]()
![]()
Routine Maintenance: After the water pump stops, stop the fan 30 minutes later to allow the evaporative cooling pads to dry. After the system stops running, check that the water tank has been drained.
Rodent Control: During seasons when the evaporative cooling pads are not in use, rodent control measures can be taken, such as installing rodent-proof netting or spraying rodenticide on the lower part of the pads. (Rodent-proof netting is not included with our evaporative cooling pads.)
Cleaning the Evaporative Cooling Pads: Remove scale and algae from the surface of the evaporative cooling pads. Use a soft brush to clean up and down, minimizing horizontal brushing. (You can brush a portion first to check if the pads can withstand brushing.) Then, only turn on the water supply system to rinse the surface of the pads to remove scale and algae. (Minimize the use of steam or high-pressure water to rinse the evaporative cooling pads.)
![]()